You are here: Home > About Us > Datacenter > Power

orange_arrowHome
orange_arrowAbout Edge Web
    blue_arrowSupport
    blue_arrowSelf Healing Servers
    blue_arrowError Notification
    blue_arrowHardware
    blue_arrowAdvanced Software
    blue_arrowMonitoring
    blue_arrowSecurity
    blue_arrowOur Network
    blue_arrowOur Datacenter
        -Structure
        -Security
        -Power
        -HVAC
        -Fire Protection
        -Connectivity
    blue_arrowSLA
    blue_arrowTestimonials
    blue_arrowAwards
    blue_arrowAUP
    blue_arrowTerms and Conditions
    blue_arrowWarranty and Disclaimer
    blue_arrowPrivacy Statement
    blue_arrowColdFusion Quick Fix
    blue_arrowResources
orange_arrowServices
    blue_arrowManaged Servers
    blue_arrowColocation
    blue_arrowClusters
    blue_arrowAnti-Spam
    blue_arrowShared Hosting
    blue_arrowDevelopment
    blue_arrowFee Schedules
orange_arrowResellers
orange_arrowSupport
    blue_arrowFAQs

Power

The building contains it’s own Baltimore Gas & Electric power substation connected to two separate Baltimore City 13,200v power grids each fed by its own set of two additional substations. Our facility is fed directly by grid power at 13.2kv and transformed to 480v within our facility which is then filtered by a high capacity Transient Voltage Surge Suppression System (TVSS) filtering all grid power disturbances up to 1,000,000 Amps.

To ensure no downtime in the case of a power grid or transformer disruption, power is then distributed to two completely separate, purposefully non-paralleled, but Phase Synchronized, 300kW PowerWare UPS systems. Each is capable of maintaining 100% of our power load allowing for fully maintenance concurrency of all electrical gear with no down time. A separate Maintenance Bypass has been installed on each UPS allowing complete bypass of either UPS system incase of system malfunction.

Power is then transformed to usable 208/120 power, run through another TVSS and individually delivered from each UPS to each rack to a rack mounted fast switch which selects the best power source from each UPS and also allows for user control of each outlet within a rack via a web interface.

In the event of a longer power grid disruption, a 750 kW generator with a 2300 Gallon (48 hour) fuel supply is in place to backup utility grid power incase of failure. Diesel is delivered to the generator via a Dual Diesel pump package is installed for fuel system redundancy.

© 2006 All information copyright Atlantic Computer Systems & Services , Incorporated and Edgewebhosting.net. All rights reserved. All content is protected by Title 17, U.S.C.S. and the Copyright Act of 1975. Any unauthorized use or duplication of the information or content on this site is strictly prohibited without expressed written consent of the copyright owners. All trademarks are property of their respective owners.